Hantek DSO4254C

Hantek DSO4254C Digital Oscilloscope User Manual

Model: DSO4254C

Marka: Hantek

1. Uvod

The Hantek DSO4254C is a versatile 4-channel digital storage oscilloscope integrated with a 1-channel arbitrary/function waveform generator. Designed for ease of use, it features independent controls for both oscilloscope and waveform generator functions. With a bandwidth of 250MHz and a 1GS/s sample rate, it offers advanced digital triggering, high sensitivity, and a clear 7-inch 64K color TFT display (800*480 pixels).

2. Ključne karakteristike

  • 4-Channel Oscilloscope with EXT, DVM, and Auto Range Function.
  • 250MHz Bandwidth, minimum measurement range 500μV/div, 1GS/s sample rate.
  • Over 32 types of automatic measurement functions.
  • Advanced digital trigger system with high trigger sensitivity and low trigger jitter.
  • Over 14 types of trigger functions: Edge, Overtime, Pulse, Pattern, Interval, UART, CAN, SPI, I2C, etc.
  • Integrated Function/Arbitrary Signal Generator: 25MHz, 12-bit resolution, 200MHz DDS, capable of generating ARB, square, sine, triangular, trapezoidal, impulse, and DC waveforms.
  • Integrated USB Host/Device for convenient PC communication and U-stick storage/system updates.
  • Supports a variety of SCPI remote control commands.
  • Optional ports: RS232, LAN, HDMI, touch screen, WIFI communication, SD card storage.
  • Stable and reliable quality, sturdy and durable construction.

3. Sadržaj paketa

The following items are included with your Hantek DSO4254C Digital Oscilloscope:

  • USB computer communication line x 1
  • Sonda x 4
  • 110-230V široki voltage-power line x 1
  • Signal output line (BNC to BNC) x 1
  • Sertifikat x 1
Hantek DSO4254C Oscilloscope and included accessories
Figure 1: Hantek DSO4254C Oscilloscope and included accessories.

4. Podešavanje

  1. Priključak za napajanje: Connect the provided 110-230V wide voltage-power line to the oscilloscope's power input and a suitable power outlet.

  2. Povezivanje sonde: Connect the oscilloscope probes to the desired input channels (1, 2, 3, or 4) on the front panel. Ensure a secure connection.

  3. Signal Generator Connection (Optional): If using the integrated signal generator, connect the signal output line (BNC to BNC) from the 'Gen Out' port to the device under test or an oscilloscope input channel for monitoring.

  4. USB priključak (opciono): For PC communication or system updates, connect the USB communication line from the oscilloscope's USB port to your computer.

  5. Uključeno: Press the recessed power button located on the front panel. You may need to use a fingernail to fully engage the button.

  6. Kalibracija sonde: Before taking measurements, it is recommended to calibrate all four probes. Connect a probe to the calibrator output (1kHz, 1V) on the front panel and adjust the probe compensation for a flat-top square wave display.

Front view of the Hantek DSO4254C Oscilloscope
Slika 2: Prednja strana view of the Hantek DSO4254C Oscilloscope, showing input channels and controls.

5. Uputstvo za upotrebu

5.1. Basic Oscilloscope Operation

  • Vertikalne kontrole: Use the vertical knobs for each channel (1-4) to adjust the voltage scale (V/div) and vertical position of the waveform.
  • Horizontalne kontrole: Use the horizontal knobs to adjust the time base (s/div) and horizontal position of the waveform.
  • Sistem okidanja: The trigger system allows for stable waveform display. Access trigger settings via the 'Trigger' menu. You can select trigger type (Edge, Pulse, Video, etc.), source channel, slope, and level. The advanced trigger functions include options for UART, CAN, SPI, and I2C buses.
  • Automatsko skaliranje: Press the 'Auto Scale' button for automatic adjustment of vertical and horizontal settings to display a stable waveform.

5.2. Mathematics Functions

The oscilloscope supports various mathematical operations on waveforms. Access the 'Math' menu to select operators (e.g., +, -, *, /) and source channels. This allows for complex signal analysis, such as adding or subtracting signals from different channels.

5.3. Funkcije mjerenja

  • automatska mjerenja: The device offers over 32 types of automatic measurements. Access the 'Measure' menu to select parameters like frequency, period, amplitude, Vmax, Vmin, Vpp, etc.
  • Mjerenja kursora: Use the 'Cursor' function to manually measure voltage and time differences on the waveform.

5.4. Waveform Generator

The integrated waveform generator can produce various signal types:

  • Sinusni talas
  • Kvadratni talas
  • Ramp (Triangular/Trapezoidal)
  • Puls
  • Buka
  • DC
  • Arbitrary waveforms (Arb1, Arb2, Arb3, Arb4)

Access the 'Wave Gen' menu to select the waveform type, frequency (up to 25MHz), amplitude (up to 1.5V), and offset. You can also load custom arbitrary waveforms from a USB flash drive.

Oscilloscope displaying multiple waveforms and measurement data
Figure 3: Oscilloscope displaying multiple waveforms and measurement data.
Oscilloscope trigger settings menu
Figure 4: Oscilloscope trigger settings menu, showing various trigger types.
Oscilloscope waveform generator settings menu
Figure 5: Oscilloscope waveform generator settings menu, showing waveform types and parameters.

5.5. Saving and Updating

  • USB pohrana: The oscilloscope supports U-stick storage for saving waveforms, settings, and screenshots. Insert a USB flash drive into the front panel USB host port.
  • Ažuriranje sistema: Firmware updates can be performed via the USB device port. Refer to the official Hantek webstranica za najnoviji firmver i upute.

6. Održavanje

  • čišćenje: Use a soft, dry cloth to clean the exterior of the oscilloscope. Do not use abrasive cleaners or solvents.
  • Skladištenje: Store the oscilloscope in a dry, dust-free environment when not in use.
  • Ažuriranja softvera: Redovno provjeravajte proizvođačeve webstranica za ažuriranja firmvera kako bi se osigurale optimalne performanse i pristup novim funkcijama.

7. Otkrivanje problema

  • Nema napajanja: Ensure the power cable is securely connected to both the oscilloscope and a working power outlet. Check the power button is fully pressed.
  • Nema prikaza talasnog oblika: Verify probes are correctly connected to the input channels and the device under test. Check the vertical and horizontal scale settings, and ensure the trigger is properly configured or use the 'Auto Scale' function.
  • Problemi sa softverom: If experiencing issues with PC communication or custom waveform generation software, ensure all required drivers and libraries are installed. Compatibility issues with older operating systems (e.g., Windows 7) may occur.
  • Netačna mjerenja: Perform probe calibration as described in the Setup section.

8. Specifikacije

FeatureSpecifikacija
Brand NameHantek
Broj modelaHantek DSO4254C
HANTEK ModelDSO4254C
Digitalni kanali4
Band Width250MHz (100-349MHz range)
Real Time Sampling Rate1GSa/S
Record Length64K (4KSa from JSON, 64K from image)
Max Waveform Capture Rate30,000wfm/s
Rezolucija ekrana800*480 piksela
Veličina ekrana7 inča i više
CertifikacijaCE
DIY SuppliesElektrični
Porijeklokontinentalna Kina
Baterija uključenabr
IS baterija se može skinutibr
Visoko zabrinjavajuća hemikalijaNema
Generator talasnih oblika25MHz, 12Bits resolution, 200MHz DDS
Detailed specifications table for Hantek DSO4254C
Figure 6: Detailed specifications of the Hantek DSO4254C.

9. Savjeti za korisnike

  • Ažuriranje firmvera: It is highly recommended to check for and install the latest firmware updates upon receiving your oscilloscope to ensure optimal performance and access to the newest features.
  • Dugme za napajanje: The power button is recessed into the casing. You may need to use a fingernail to press it fully and ensure the device powers on correctly.
  • Synchronization Knob: The synchronization knob is relatively small compared to the amplitude adjustment knobs. Take care when adjusting it.
  • Custom Waveform Software: If you plan to use the software for generating custom arbitrary waveforms, be aware that there might be compatibility issues with older operating systems like Windows 7.
  • Jezička podrška: The oscilloscope's firmware may not include Russian language support, offering only English and a few other European languages.

10. Garancija i podrška

For any technical assistance, warranty claims, or further inquiries, please contact the seller or the manufacturer directly. Refer to your purchase documentation for specific warranty terms and contact information.

11. Proizvod je gotovview Video

Video 1: Raspakivanje i početni prikazview of the Hantek DSO4254C Digital Oscilloscope, demonstrating its physical features and basic functions.

Povezani dokumenti - DSO4254C

Preview DSO4000BC 系列数字存储示波器用户手册
本手册提供了Hantek DSO4000BC系列数字存储示波器的详细操作指南、安全注意事项、功能介绍及故障排除方法,帮助用户充分了解和使用该设备。
Preview Hantek 6022BE Korisnički priručnik: Vodič za prijenosni PC osciloskop
Preuzmite korisnički priručnik za Hantek 6022BE za ovaj prenosivi USB osciloskop za računar. Saznajte više o njegovim karakteristikama, podešavanju, radu i rješavanju problema za testiranje, istraživanje i obrazovne primjene.
Preview Hantek DSO2D20 serija digitalnih osciloskopa - uputstvo za upotrebu
Sveobuhvatno korisničko uputstvo za digitalne osciloskope serije Hantek DSO2D20, koje detaljno opisuje karakteristike, rad, rješavanje problema i specifikacije za preciznu analizu signala.
Preview Hantek2000 Series Handheld Oscilloscope User Manual
Comprehensive user manual for the Hantek2000 Series handheld oscilloscopes, detailing features, operation, DMM functions, signal generation, troubleshooting, and technical specifications for models like Hantek2C72, Hantek2C42, Hantek2D72, and Hantek2D42.
Preview Hantek 6000BC/BD/6074BE Cifrovoj oscilograf - Rukovodstvo korisnika
Potpuno uputstvo korisnika za cifrove oscilografe Hantek serije 6000BC, 6000BD i 6074BE. Opis funkcija, nastrojeka, primjera korištenja i tehničkih karakteristika.
Preview Hantek DSO2D20 数字示波器用户手册 - 操作与功能指南
获取 Hantek DSO2D20系列数字示波器的官方用户手册.技术、触发模式、系统配置及故障排除,是用户掌握和高效使用该示波噀