Shahe ANC Series Digital Torque Adapter

Shahe Digital Torque Wrench Adapter User Manual

Models: ANC-30, ANC-135, ANC-200, ANC-340

1. Uvod

The Shahe Digital Torque Wrench Adapter is a precision instrument designed for monitoring and controlling torque during fastening and disassembly tasks. It is suitable for a wide range of applications, including automotive, bicycle, and general mechanical maintenance. This manual provides detailed instructions for its proper use, ensuring accuracy and extending the product's lifespan.

For a comprehensive PDF version of this manual, please refer to the Digital Torque Meter Instruction Manual (PDF).

2. Ključne karakteristike

  • visoka preciznost: Bidirectional reading error of ±2% clockwise and ±2.5% counterclockwise.
  • Više jedinica: Supports four torque units: kgf.cm, N.m, lbf.ft, and lbf.in.
  • Zvučni i vizuelni alarmi: Provides beeping alarms and a red indicator light to prevent over-tightening.
  • Funkcija pozadinskog osvjetljenja: Ensures clear data readability in low-light conditions.
  • Multi-mode Operation: Includes Real-time (Track), Peak, and Preset modes.
  • Automatsko isključivanje: Isključuje se nakon 10 minuta neaktivnosti radi uštede baterije.
  • Pohrana podataka: Ability to save and view očitavanja obrtnog momenta.

3. Komponente proizvoda i višeview

The digital torque wrench adapter comes with the main unit and various accessories depending on the model. Below is a diagram illustrating the main components and controls of the device.

Diagram of Shahe Digital Torque Adapter with labeled parts: Display screen, Buzzer (rear), Indicator light, Switch, Plus(+) button, Minus(-) button, Save button, Setting button, Switch button.
Figure 1: Digital Torque Adapter Components
Shahe Digital Torque Adapter in its protective case with instruction manual and adapters.
Slika 2: Pakovanje i sadržaj proizvoda

Paket obično uključuje:

  • Digital Torque Meter (1 pc)
  • AAA Batteries (2 pcs, not included in some models)
  • Uputstvo za upotrebu (1 kom)
  • Certificate of Conformity (1 pc)
  • Garantni list (1 kom)
  • Desiccant (1 bag)
  • Adapters (Quantity varies based on model: 2 pcs for 1/2" adapter size; 1 pc for 1/4" or 3/8" adapter size).

4. Postavljanje i početna upotreba

4.1. Instalacija baterije

The device requires two 1.5V AAA batteries. Open the battery compartment, insert the batteries according to the polarity markings, and close the compartment securely.

4.2. Uključivanje

Kratko pritisnite P/C button to turn on the device. If the battery display indicates insufficient power upon startup, the device will automatically shut down. Replace the batteries to ensure normal operation.

Diagram showing the buttons on the torque adapter: Plus(+), Minus(-), M (Save), U/S (Settings), P/C (Switch).
Slika 3: Kontrolni gumbi

4.3. Attaching Adapters

The digital torque adapter is designed to be used with various drive sizes. Depending on your model, it may come with 1/4'', 3/8'', or 1/2'' adapters. Select the appropriate adapter for your application and securely attach it to the square drive of the torque meter.

Image showing the digital torque adapter with 1/2 inch drive and additional 3/8 inch (10mm) and 1/4 inch (6.3mm) adapters.
Figure 4: Multiple Connector Adapters

5. Uputstvo za upotrebu

5.1. Prebacivanje jedinica

Dok je uređaj uključen, pritisnite U/S button to cycle through the four available engineering units: kgf.cm, N.m, lbf.ft, and lbf.in.

Prikaz examples of unit conversion showing lbf.ft, lbf.in, kgf.cm, and N.m on the digital screen.
Figure 5: Unit Conversion Display

5.2. Working Mode Switch

From the measurement interface, with no torque value displayed, press the M button to switch between the following modes:

  • Real-time Mode (Track): The displayed torque value changes continuously as force is applied and released. When force is removed, the display returns to 0.
  • Peak Mode (Peak): After applying force, the display will show and lock the maximum torque value achieved during the application. This value will flash. Press the P/C button to clear the peak torque. You can re-apply force to update the locked peak torque without clearing.
  • Preset Mode (Pre): In this mode, you can set a target torque value. The display will show the current torque as force is applied. Alarms will activate as you approach the preset value.

5.3. Sound and Light Alarm Function

Ensure the buzzer function is turned on in the settings (see section 5.9). In Preset Mode, as the applied torque approaches 80% of the preset value, the red LED light will flash, and the buzzer will sound. As the torque gets closer to the preset value, the light will flash faster, and the buzzer will sound more rapidly. When 100% of the preset value is reached, the red LED light will remain on, and the buzzer will sound continuously. The alarms will cease as the torque reduces.

Image showing the digital torque adapter with a red indicator light on, signifying an alarm.
Figure 6: Audible and Visual Alarms

5.4. Clear Function

If a torque value is displayed on the screen, a short press of the P/C button will clear the display and reset the measurement.

5.5. Pohranjivanje podataka

Tokom mjerenja, pritisnite dugme M button lightly to save the current torque value. The display will show "Succ" to confirm successful saving. The upper left corner of the screen will indicate the number of saved data entries.

5.6. Podaci View

From the non-operation measurement interface, long press the M dugme za view all saved data. Use the + or - buttons to navigate through individual data entries. To exit, tap the M ponovo dugme.

5.7. Data Deletion

In the data viewing interface, tap the U/S button to select the deletion mode: "ALL" (delete all data) or "ONE" (delete data one by one, starting from the last entry). After selecting, tap the P/C button to execute the deletion. Note: Deleting "ONE" by selection is not feasible; it deletes the last entry. An error code "JEL" may appear if an invalid operation is attempted.

5.8. Vratite tvorničke postavke

From the measurement interface, long press the U/S button to enter the system settings. Then, short press U/S to select "RSET". Use the + button to select "1" for restore or "0" to cancel. Tap U/S to confirm. The device will initialize and return to the measurement interface. To exit without restoring, select "0" or tap P/C.

5.9. Buzzer Control

From the measurement interface, long press the U/S button to enter system settings. Short press U/S to select "BUZZ". Use the + button to select "1" to turn the buzzer on or "0" to turn it off. Tap P/C za izlaz.

5.10. Kontrola pozadinskog osvjetljenja

From the measurement interface, long press the U/S button to enter system settings. Short press U/S to select "LTON". Use the + button to select "1" to turn the backlight on or "0" to turn it off. Tap P/C za izlaz.

6. Specifikacije

The following table details the specifications for various models of the Shahe Digital Torque Wrench Adapter:

ModelANC-30ANC-135ANC-200ANC-340
Minimum Graduation Value0.01 Nm0.1 Nm0.1 Nm0.1 Nm
Maksimalni radni domet0.9-30 Nm4-135 Nm6-200 Nm10-340 Nm
Konektor1/4'' or 1/2''1/2''1/2''1/2''
Preciznost obrtnog momenta±2% clockwise; ±2.5% counterclockwise
MaterijalChromium-vanadium Steel
Baterija2 pieces 1.5V AAA battery (not included)
Automatsko isključivanjeWithout operation for 10 minutes

Note: Some models (30N.M and 135N.M) may have different configurations regarding connector sizes.

7. Održavanje i skladištenje

  • Rekalibracija: To maintain accuracy, it is recommended to recalibrate the device approximately once a year.
  • Avoid Over-range: Do not use the torque meter beyond its maximum operating range (120% of full scale). Exceeding this limit can cause permanent damage or loss of accuracy.
  • Pažljivo rukujte: Avoid violently shaking or dropping the torque meter.
  • Uslovi okoline: Do not store or operate the device in high temperatures, high humidity, or direct sunlight.
  • Vlaga: If the torque meter gets wet, wipe it immediately with a dry towel.
  • LCD ekran: Do not apply excessive pressure to the LCD screen.

8. Otkrivanje problema

  • "OLOAD" Display: If the screen displays "OLOAD", it indicates that the torque has exceeded 120% of the full scale. Remove the applied torque immediately, then press the P/C button to recover. If the issue persists, contact the manufacturer.
  • Device Shuts Down on Startup: This usually indicates low battery. Replace the two 1.5V AAA batteries.
  • Netačna očitavanja: Ensure the device is recalibrated annually. Avoid using it beyond its specified maximum operating range.

9. Savjeti za korisnike

  • Aktivacija alarma: Remember that the backlight and buzzer functions for alarms activate only when the target or rated torque value is reached.
  • Jedinice obrtnog momenta: The device measures torque in standard units (N.m, lbf.ft, lbf.in, kgf.cm), not in degrees.
  • Model Updates: Be aware that product parts and designs may be updated. For example, newer models may not include a screwdriver as part of the standard package. Always refer to the latest product information.
Image showing an old model of the Shahe ANC Digital Torque Adapter next to a new model, indicating that the new model does not include a screwdriver.
Figure 7: Model Update Notification (Screwdriver not included in new models)

10. Garancija i podrška

This product includes a Warranty Card and a Certificate of Conformity. Please retain these documents for any warranty claims or support inquiries. For technical assistance or further questions, please contact your vendor or the manufacturer directly.

Povezani dokumenti - ANC Series Digital Torque Adapter

Preview Shahe Pre-set Torque Screwdriver User Manual - Specifications and Operation Guide
Comprehensive user manual for the Shahe pre-set torque screwdriver, covering its overview, functional features, detailed specifications, product structure, step-by-step usage instructions, important safety precautions, and maintenance guidelines.
Preview SHAHE Pre-set Torque Screwdriver User Manual - Model SHANHR-GSQ
User manual for the SHAHE SHANHR-GSQ pre-set torque screwdriver, detailing its overview, functional features, specifications, usage, maintenance, and important safety precautions for precise fastener tightening.
Preview 数显扭矩起子使用说明书 - Shahe
Shahe数显扭矩起子用户手册,详细介绍了产品的功能特点、规格型号、罕术号、技术参说明、维修保养及随机附件。适用于精密制造行业小扭矩紧固件装配和悀
Preview SHAHE IP67 digitalna čeljust korisnički priručnik
Korisnički priručnik za SHAHE IP67 digitalno pomično mjerilo, s detaljnim opisom njegovih karakteristika, tehničkih specifikacija, sigurnosnih mjera opreza, uputa i rješavanja problema. Pokriva modele 150 mm, 200 mm i 300 mm.
Preview SHAHE Digitalni inklinometar (Model 5341-90/5341-90B) - Korisnički priručnik
Uputstvo za upotrebu za SHAHE digitalni inklinometar (aluminijski okvir). Karakteristike uključuju relativno/apsolutno mjerenje, konverziju ugla/nagiba, pamćenje podataka, punjivu bateriju i jake magnete. Detaljno opisuje tehničke parametre, uputstva za upotrebu i primjenu.
Preview SHAHE Wireless Angle Gauge Instructions & Technical Specifications
User manual and technical specifications for the SHAHE Wireless Angle Gauge (Model 5346/5346-L), detailing its features, functions, safety precautions, and operational instructions.