HURRISE Model-100

HURRISE Model-100 Antistatički mjerač otpora - uputstvo za upotrebu

Precise Measurement for Conductive, Antistatic, and Static Dissipative Materials

1. Uvod

The HURRISE Model-100 Anti-Static Resistivity Meter is a precise instrument designed for accurately measuring the surface resistivity and grounding of various materials. This device is essential for evaluating conductive, antistatic, and static dissipative properties, ensuring compliance with industry standards such as ANSI ESD S20.20 and IEC61340-5-1.

Its versatile applications include engineering, maintenance, quality control, incoming inspection, manufacturing, and training environments where static control is critical.

2. Sigurnosne informacije

Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in inaccurate readings or damage to the instrument.

  • Do not expose the meter to extreme temperatures, humidity, or direct sunlight.
  • Izbjegavajte ispuštanje uređaja ili izlaganje jakim udarcima.
  • Uvjerite se da je pretinac za baterije sigurno zatvoren tokom rada.
  • Ne pokušavajte sami otvarati ili popravljati uređaj. Za sve servisne radove obratite se kvalifikovanom osoblju.
  • Keep the meter clean and free from dust and debris.

3. Proizvod je gotovview

The HURRISE Model-100 features a clear indicator panel and a simple interface for ease of use. Below is a diagram illustrating the key components of the device.

HURRISE Model-100 Anti-Static Resistivity Meter with labeled components

Slika 3.1: Front view of the HURRISE Model-100 Resistivity Meter with key components labeled. This image highlights the Flash Indicator LEDs, Insulation Indicator Light, Test Button, and Earth Leakage port.

  • Flash Indicator (LEDs): A series of LEDs indicating the measured resistance range, from 103 do 1012 Ohms per square. These LEDs are grouped into Conductive, Static Dissipative, and Insulative categories.
  • Insulation Indicator Light: A dedicated LED that illuminates when the material being tested is insulative.
  • Testno dugme: A red button used to initiate a measurement.
  • Earth Leakage Port: A connection point for an external ground wire to perform grounding tests.
  • Model-100 Label: Identifies the specific model of the resistivity meter.
  • Resistivity Meter Label: Indicates the primary function of the device.
HURRISE Model-100 Anti-Static Resistivity Meter front view

Slika 3.2: Front view of the HURRISE Model-100 Anti-Static Resistivity Meter, showing the display panel and controls.

4. Podešavanje

Before using the HURRISE Model-100, ensure it is properly set up.

4.1 Instalacija baterije

  1. Pronađite odjeljak za baterije na stražnjoj strani mjerača.
  2. Gurnite poklopac pretinca za baterije.
  3. Insert one 9V (6F22) battery, ensuring correct polarity. The device is shipped with a matching battery.
  4. Čvrsto zatvorite poklopac odeljka za baterije.
Nazad view of HURRISE Model-100 Anti-Static Resistivity Meter showing battery compartment

Slika 4.1: Nazad view of the HURRISE Model-100, illustrating the battery compartment location.

4.2 Connecting the Ground Wire (Optional)

For specific grounding tests, the included ground wire can be connected.

  1. Insert the jack end of the ground wire into the Earth Leakage port on the front of the meter.
  2. Connect the alligator clip end of the ground wire to a known ground point or the material being tested for grounding.
HURRISE Model-100 Anti-Static Resistivity Meter with battery and ground wire

Slika 4.2: The HURRISE Model-100 meter shown alongside its 9V battery and the ground wire with an alligator clip.

5. Uputstvo za upotrebu

The HURRISE Model-100 utilizes the ASTM standard D 257 parallel grid induction method for precise and high-speed measurements.

5.1 Surface Resistivity Measurement

  1. Place the meter directly onto the surface of the material you wish to test. Ensure good contact between the meter's electrodes and the material.
  2. Pritisnite i držite crvenu TEST dugme.
  3. Observe the Flash Indicator LEDs. The LED corresponding to the material's surface resistivity will illuminate.
  4. Otpustite TEST button to turn off the indicators.

5.2 Tumačenje rezultata

The illuminated LED indicates the resistance range in Ohms per square (Ω/sq).

  • Conductive: LEDs from 103 do 105 Ω/sq. Materials in this range are highly conductive and allow static charges to dissipate rapidly.
  • statički disipativni: LEDs from 106 do 1010 Ω/sq. These materials allow static charges to dissipate at a controlled rate, preventing rapid discharge.
  • Insulative: LEDs at 1011 Ω/sq and 1012 Ω/sq, or the dedicated Insulation Indicator Light. Materials in this range resist the flow of static charges and can accumulate them.

5.3 Grounding Measurement (using Earth Leakage Port)

To measure the resistance to ground, connect the ground wire as described in Section 4.2.

  1. Connect the alligator clip of the ground wire to the material or object whose resistance to ground you wish to measure.
  2. Place the meter on the material, ensuring good contact.
  3. Pritisnite i držite crvenu TEST dugme.
  4. Read the illuminated LED indicator to determine the resistance to ground.

6. Održavanje

6.1 Čišćenje

Wipe the meter with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the ABS material and electronic components.

6.2 Zamjena baterije

When the indicator lights become dim or the meter fails to power on, replace the 9V battery as described in Section 4.1. Remove the battery if the meter will not be used for an extended period to prevent leakage.

6.3 Skladištenje

Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures. Keep it in its original packaging or a protective case to prevent damage.

7. Otkrivanje problema

  • Mjerač se ne uključuje: Provjerite je li 9V baterija ispravno instalirana i dovoljno napunjena. Zamijenite bateriju ako je potrebno.
  • Nedosljedna ili nikakva očitavanja: Ensure the meter's electrodes are making firm and clean contact with the material surface. Clean the electrodes if they appear dirty. Verify the material is suitable for testing.
  • Readings affected by humidity: Note that humidity levels above 65%RH can affect the measurement accuracy of the instrument. Perform tests in a controlled environment if precise readings are critical.

8. Specifikacije

FeatureSpecifikacija
ModelModel-100
MaterijalABS
Baterija1 x 6F22 9V battery, 800mAh capacity
Kontinuirano radno vrijemeViše od 40 sati
Mjerenje temperaturnog opsega40°F do 120°F (5°C do 49°C)
Measurement Humidity Range5% to 90%RH (accuracy affected above 65%RH)
Dimenzije (paket)5.51 x 4.33 x 1.97 inča
Težina (paket)6.84 unce
Usklađenost sa standardimaANSI ESD S20.20, IEC61340-5-1, ASTM D 257

9. Garancija i podrška

For warranty information or technical support, please refer to the documentation provided with your purchase or contact HURRISE customer service through the retailer where the product was acquired. Keep your purchase receipt as proof of purchase.

© 2024 HURRISE. All rights reserved.