Lutron YK-37UVSD

Lutron YK-37UVSD UVA and UVC Light Meter Instruction Manual

Model: YK-37UVSD

1. Uvod

The Lutron YK-37UVSD is a professional-grade light meter designed for accurate measurement of both UVA and UVC light. This device features a microprocessor circuit for high reliability and durability, making it suitable for various applications including monitoring blue light radiation hazards, UV sterilization, graphic arts, photochemical matching, UV EPROM erasure, photoresist exposure, and curing of inks, adhesives, and coatings. It includes an SD card real-time data logger and supports Type K temperature measurements.

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your YK-37UVSD light meter.

2. Sigurnosne informacije

3. Proizvod je gotovview

3.1 Glavna jedinica

The main unit features an LCD display, control buttons for power, function, data hold, recording, zero adjustment, and data logging. It also includes slots for the SD card and probe connections.

Lutron YK-37UVSD Main Unit

Slika 1: Front view of the Lutron YK-37UVSD main unit, showing the LCD display and control buttons.

3.2 UVA and UVC Probes

The meter comes with two specialized probes: one for UVA measurement and another for UVC measurement. Both probes feature a cosine correction filter for accurate light detection.

UVA and UVC Probes for Lutron YK-37UVSD

Slika 2: Separate UVA and UVC probes. The UVA probe has a cylindrical body, while the UVC probe has a flat, circular sensor head.

4. Podešavanje

4.1 Instalacija baterije

  1. Locate the battery compartment cover on the back of the main unit.
  2. Otvorite poklopac.
  3. Insert six (6) 1.5V AA (UM-3) batteries, ensuring correct polarity as indicated inside the compartment.
  4. Vratite poklopac odeljka za baterije.

4.2 Povezivanje sonde

  1. Identify the desired probe (UVA or UVC) for your measurement.
  2. Connect the probe's cable connector to the corresponding input jack on the top or side of the main unit. Ensure a secure connection.

4.3 Umetanje SD kartice

  1. Locate the SD card slot on the side of the main unit.
  2. Insert a formatted SD card (up to 16 GB) into the slot until it clicks into place.
  3. Da biste uklonili, lagano gurnite karticu prema unutra dok ne iskoči.

5. Uputstvo za upotrebu

5.1 Uključivanje/isključivanje

Pritisnite POWER/ESC button to turn the meter on. Press and hold the POWER/ESC dugme nekoliko sekundi da biste ga isključili.

5.2 Measurement Mode Selection

After powering on, the meter will display the current measurement mode. To switch between UVA and UVC modes, press the dedicated UVA/UVC button (if available) or cycle through modes using the FUNC/HOLD/NEXT button as per the on-screen prompts.

5.3 Odabir raspona

The YK-37UVSD offers two measurement ranges: 2 mW/cm² and 20 mW/cm². The meter typically auto-ranges, but you may be able to manually select a range using the SET button or a combination of buttons as described in the on-screen menu.

5.4 Funkcija zadržavanja podataka

Pritisnite HOLD dugme (često u kombinaciji sa FUNC/NEXT) to freeze the current reading on the display. Press it again to release the hold function.

5.5 Podešavanje nule

For accurate measurements, especially in low light conditions, a zero adjustment may be necessary. With the probe covered or in a dark environment, press the NULA button to calibrate the meter to zero.

5.6 Data Logging (SD Card)

To initiate real-time data logging to the SD card:

  1. Provjerite je li SD kartica umetnuta.
  2. Pritisnite LOGGER button. The display will indicate that logging has started.
  3. To stop logging, press the LOGGER ponovo dugme.
  4. Data is saved in a format compatible with spreadsheet software for easy analysis.

5.7 Type K Temperature Measurement

The YK-37UVSD also supports Type K thermocouple temperature measurements. Connect a Type K thermocouple probe (sold separately) to the designated input. Use the FUNC/NEXT button to switch to temperature measurement mode.

6. Održavanje

6.1 Čišćenje

Wipe the device and probes with a soft, dry cloth. For stubborn dirt, a slightly damp Može se koristiti krpa s blagim deterdžentom, pazeći da tekućina ne uđe u uređaj. Ne koristite abrazivna sredstva za čišćenje ili rastvarače.

6.2 Zamjena baterije

When the low battery indicator appears on the display, replace all six AA batteries promptly to ensure continued accurate operation. Refer to section 4.1 for battery installation instructions.

6.3 Skladištenje

Store the meter and probes in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for an extended period, remove the batteries to prevent leakage.

7. Otkrivanje problema

Ako problemi i dalje postoje nakon isprobavanja ovih rješenja, obratite se korisničkoj podršci.

8. Specifikacije

The following table outlines the key specifications of the Lutron YK-37UVSD UVA and UVC Light Meter:

Lutron YK-37UVSD Detailed Specifications Sheet

Slika 3: Detailed specification sheet for the Lutron YK-37UVSD, providing comprehensive technical data.

FeatureSpecifikacija
ModelYK-37UVSD
Measurement RangesUVA: 2 mW/cm², 20 mW/cm²
UVC: 2 mW/cm², 20 mW/cm²
Tip senzoraUVA probe, UVC probe with cosine correction filter
DisplayLCD
Data LoggerSD Card (1 GB to 16 GB), Real-time data logging
Merenje temperatureType K Thermocouple (optional probe)
Napajanje6 x 1.5V AA (UM-3) batteries or DC 9V adapter
Radna vlažnostManje od 85% RH
Dimenzije (glavna jedinica)Približno 203 x 76 x 38 mm (8 x 3 x 1.5 inča)
Težina (glavna jedinica)Pribl. 300 g (0.66 lbs)
Zemlja porijeklaTajvan
Težina artikla426 g
Dimenzije proizvoda30.48 x 15.24 x 10.16 cm

9. Garancija i podrška

9.1 Informacije o garanciji

This product is manufactured by Lutron. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact the manufacturer directly. Warranty coverage typically includes defects in materials and workmanship under normal use.

9.2 Korisnička podrška

For technical assistance, troubleshooting not covered in this manual, or service inquiries, please contact the seller or the authorized Lutron service center in your region. Please have your model number (YK-37UVSD) and purchase information ready when contacting support.