KEESON ETA23

KEESON Babycare TENS Elle TENS 2

Uputstvo za upotrebu

1. Uvod

The KEESON Babycare TENS Elle TENS 2 is a Transcutaneous Electrical Nerve Stimulation (TENS) device designed to provide drug-free pain relief during labor and post-natal recovery. It features dual-channel operation, a contraction timer, and Opti-Max Technology to enhance pain management. This manual provides essential information for safe and effective use of your device.

2. Sigurnosne informacije i upozorenja

Please read all instructions carefully before using the device. Failure to do so may result in injury or improper operation.

  • Do not use if you have a pacemaker or any other implanted electronic device.
  • Do not use if you have a heart condition or epilepsy.
  • Do not use on broken skin, open wounds, or areas of infection.
  • Do not use near or over the eyes, mouth, front of the neck, or across the chest.
  • Consult your doctor or midwife before use if you have any medical concerns.
  • Čuvati van domašaja djece.
  • This device is intended for external use only.
  • Discontinue use if you experience any discomfort or adverse reactions.

3. Sadržaj paketa

Prilikom otvaranja kutije, molimo Vas da se uvjerite da su prisutni svi sljedeći elementi:

  • 1 x Elle TENS 2 unit
  • 4 x Self-adhesive electrode pads (50x100mm)
  • 2 x Lead wires
  • 2 x AA baterije (1.5V)
  • 1 x gajtan za vrat
  • 1 x Uputstvo za upotrebu (ovaj dokument)
Elle TENS 2 unit with electrode pads, lead wires, and batteries

Image 3.1: Contents of the Elle TENS 2 package, including the main unit, electrode pads, lead wires, and batteries.

4. Device Overview

Familiarize yourself with the various parts and controls of your Elle TENS 2 unit:

Close-up of Elle TENS 2 front panel with screen and buttons

Slika 4.1: Prednja strana view of the Elle TENS 2 device, showing the display screen, control buttons, and branding.

  • LCD ekran: Shows program mode, intensity levels, contraction timer, and battery status.
  • Power Button (Ⓘ): Uključuje/isključuje uređaj.
  • Contraction Timer Button: Starts and stops the contraction timer.
  • Opti-Max Button: Activates the Opti-Max function for enhanced pain relief.
  • CH1 Intensity Buttons (+/-): Adjusts intensity for Channel 1.
  • CH2 Intensity Buttons (+/-): Adjusts intensity for Channel 2.
  • Dugme za način rada: Cycles through available TENS programs.
  • Dugme za pojačavanje: Provides an immediate surge of intensity for acute pain during contractions.
  • CT History Button: Displays the history of recorded contractions.
  • Lead Wire Ports: Located at the top of the device for connecting electrode lead wires.
Nazad view of Elle TENS 2 showing battery compartment and neck cord attachment

Slika 4.2: Pozadi view of the Elle TENS 2, illustrating the battery compartment and the attachment point for the neck cord.

5. Podešavanje

Follow these steps to prepare your Elle TENS 2 for use:

  1. Umetnite baterije: Open the battery compartment on the back of the unit. Insert the two AA batteries, ensuring correct polarity (+/-). Close the compartment securely.
  2. Connect Lead Wires: Plug the lead wires into the ports at the top of the Elle TENS 2 unit. Each lead wire has two pins that connect to two electrode pads.
Elle TENS 2 with lead wires connected to the top ports

Image 5.1: The Elle TENS 2 device with lead wires properly inserted into the top connection ports.

  1. Pričvrstite elektrode: Connect the electrode pads to the pins on the lead wires. Ensure a secure connection.
  2. Pripremite kožu: Ensure the skin where electrodes will be placed is clean, dry, and free from oils or lotions.
  3. Electrode Placement for Labor: For labor pain relief, place the four electrode pads on your back as shown in the diagram below. Two pads should be placed on either side of the spine, just below the bra line, and the other two pads on either side of the spine, just above the sacrum (lower back). Ensure pads are not touching each other.
Elle TENS 2 connected to four electrode pads

Image 5.2: The Elle TENS 2 unit with all four electrode pads connected via lead wires, ready for application.

For post-natal pain relief, consult your healthcare professional for appropriate electrode placement.

6. Uputstvo za upotrebu

Using your Elle TENS 2 device:

  1. Uključi: Press and hold the Power button (Ⓘ) until the display illuminates. The device will start in a default program mode.
  2. Podesite intenzitet: Use the CH1 (+/-) buttons to increase or decrease the intensity for Channel 1 (upper pads) and CH2 (+/-) buttons for Channel 2 (lower pads). Start with a low intensity and gradually increase until you feel a strong, comfortable tingling sensation. Avoid setting the intensity too high, which can cause discomfort.
  3. Odaberite način rada: Press the 'Mode' button to cycle through the available programs. The Elle TENS 2 typically offers different modes (e.g., Burst, Continuous) suitable for various stages of labor. Refer to your midwife's advice on which mode to use.
  4. Contraction Timer: Press the 'Contraction Timer' button at the start of a contraction. Press it again when the contraction ends. The display will show the duration of the contraction and the interval between contractions. Press 'CT History' to view a summary of recent contractions.
  5. Funkcija pojačanja: During a contraction, press the 'Boost' button for an immediate, stronger burst of stimulation to help manage acute pain. Release the button to return to the previous intensity.
  6. Opti-Max Technology: Press the 'Opti-Max' button to activate this feature, which provides an additional level of pain relief by automatically adjusting stimulation parameters.
  7. Isključi: Press and hold the Power button (Ⓘ) until the display turns off. Always turn off the device before removing electrodes.
Elle TENS 2 device held in a hand, showing its compact size

Image 6.1: The Elle TENS 2 unit comfortably held in a hand, demonstrating its ergonomic design and portability.

7. Održavanje

Proper care will extend the life of your Elle TENS 2 device:

  • čišćenje: Obrišite uređaj s oglasomamp cloth and mild soap. Do not immerse the unit in water or use abrasive cleaners.
  • Jastučići za elektrode: After each use, re-apply the protective film to the electrode pads and store them in a sealed bag to maintain their adhesive quality. Replace pads when they lose their stickiness or become damaged.
  • Zamjena baterije: When the battery indicator on the display shows low power, replace both AA batteries with new ones. Remove batteries if the device will not be used for an extended period.
  • Skladištenje: Uređaj i pribor čuvajte na hladnom i suhom mjestu, dalje od direktne sunčeve svjetlosti i ekstremnih temperatura.

8. Otkrivanje problema

If you encounter issues with your Elle TENS 2, refer to the following table:

ProblemMogući uzrokRješenje
Nema osjeta ili slab osjet
  • Niska baterija
  • Loose lead wire connection
  • Jastučići se ne prianjaju dobro
  • Intenzitet prenizak
  • Zamijenite baterije
  • Check lead wire connections
  • Ensure pads are firmly applied; replace if necessary
  • Postepeno povećavajte intenzitet
Ekran ne radi
  • Ispraznjene baterije
  • Uređaj nije uključen
  • Zamijenite baterije
  • Pritisnite i držite dugme za napajanje
Jastučići se ne lijepe
  • Skin is oily/dirty
  • Pads are old/worn
  • Očistite kožu temeljno
  • Replace with new electrode pads

Ako problem i dalje postoji nakon isprobavanja ovih rješenja, obratite se korisničkoj podršci.

9. Specifikacije

  • Broj modela: ETA23
  • Izvor napajanja: 2 x AA baterije (uključene)
  • Kanali: Dual Channel
  • Dimenzije: Approximately 1 x 1 x 1 cm (device only)
  • Težina: Approximately 497 g (device only)
  • Proizvođač: Body Clock Healthcare Ltd.
  • Karakteristike: Contraction Timer, Opti-Max Technology, Boost button

10. Garancija i podrška

Your KEESON Babycare TENS Elle TENS 2 device is covered by a manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included in your package for specific terms and conditions.

For technical support, troubleshooting assistance, or to purchase replacement parts, please contact your retailer or the manufacturer directly. Contact information can typically be found on the product packaging or the manufacturer's official website.

© 2025 KEESON. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.