JASCO 45609

JASCO GE Z-Wave relejni prekidač za uključivanje/isključivanje (Model 45609 / ZW4001) Uputstvo za upotrebu

Your Guide to Installation and Operation

1. Uvod

This instruction manual provides comprehensive guidance for the installation, configuration, and operation of the JASCO GE Z-Wave On/Off Relay Switch, Model 45609 (ZW4001). This device is designed to integrate into your Z-Wave wireless lighting control system, enabling remote ON/OFF control of permanently installed lighting fixtures and ceiling fans.

The GE Z-Wave On/Off Relay Switch offers a convenient solution for smart home automation, compatible with various lighting types including CFL, LED, Xenon, Halogen, Fluorescent, and Incandescent. It supports both 2-way and 3-way wiring configurations when used with an auxiliary switch.

2. Važne informacije o sigurnosti

UPOZORENJE: RIZIK OD STRUJNOG UDARA. Instalacija uključuje visoku zapreminutage wiring. Improper installation can result in serious injury or death. Always consult a qualified electrician if you are unsure about any part of the installation process.

  • ISKLJUČITE NAPAJANJE: Before installation, turn OFF the power to the switch location at the circuit breaker or fuse box.
  • POTREBNA NEUTRALNA ŽICA: This switch requires a neutral wire for operation. If your existing switch box does not have a neutral wire, consult a qualified electrician.
  • SAMO ZA UNUTRAŠNU UPOTREBU: Ovaj uređaj je namijenjen za upotrebu u zatvorenom prostoru u suhim prostorijama.
  • LOAD COMPATIBILITY: Ensure the connected load does not exceed the switch's maximum rating.
  • KONTROLA VENTILATORA: This switch provides ON/OFF control for ceiling fans; speed control is not supported.

3. Sadržaj paketa

  • GE Z-Wave On/Off Relay Switch (Model 45609 / ZW4001)
  • Wiring Nuts (typically included, but may vary)
  • Uputstvo za upotrebu (ovaj dokument)

Napomena: A wallplate is not included and must be purchased separately.

4. Postavljanje i instalacija

Follow these steps carefully to install your GE Z-Wave On/Off Relay Switch. If you are unfamiliar with electrical wiring, please consult a qualified electrician.

4.1 Dijagram ožičenja iznadview

The switch requires Line (Hot), Load, Neutral, and Ground connections. For 3-way installations, an auxiliary switch (e.g., GE 45610) and a traveler wire are also required.

GE Z-Wave On/Off Relay Switch without wallplate

Slika 1: Front view of the GE Z-Wave On/Off Relay Switch (Model 45609) without a wallplate, showing the rocker switch and mounting bracket. The "TOP" indicator is visible at the top of the metal bracket. Electrical ratings (120VAC, 60Hz, 15A Resistive Load) are printed on the side.

4.2 Koraci instalacije

  1. Isključite napajanje: Locate the circuit breaker or fuse that supplies power to the switch box. Turn it OFF completely. Verify power is off using a voltage tester.
  2. Uklonite postojeći prekidač: Carefully remove the wallplate and unscrew the existing switch from the wall box. Disconnect the wires from the old switch, noting which wire was connected to which terminal. It is recommended to label the wires (Line, Load, Neutral, Ground, Traveler if applicable).
  3. Identifikujte žice:
    • Line (Hot): Connects to the electrical panel, providing power.
    • Opterećenje: Connects to the light fixture or fan.
    • neutralno: Typically white, required for the switch to operate.
    • tlo: Gola bakrena ili zelena žica.
    • Traveler (for 3-way): Connects to the auxiliary switch.
  4. Wire the Z-Wave Switch: Connect the wires to the GE Z-Wave switch terminals as follows:
    • Žica za uzemljenje: Connect to the green GROUND terminal.
    • Neutralna žica: Connect to the white NEUTRAL terminal.
    • Line (Hot) Wire: Connect to the black LINE terminal.
    • Žica za opterećenje: Connect to the black LOAD terminal.
    • Traveler Wire (if 3-way): Connect to the red TRAVELER terminal. Cap off the traveler wire if not used.
  5. Montirajte prekidač: Carefully fold the wires and push the switch into the wall box. Secure the switch with the provided screws.
  6. Instalirajte zidnu ploču: Attach the new wallplate (not included) over the switch.
  7. Vrati snagu: Ponovo uključite napajanje na prekidaču.
  8. Test funkcionalnost: Manually press the rocker switch to ensure the connected light or fan turns ON and OFF.
GE Z-Wave On/Off Relay Switch with wallplate

Slika 2: Front view of the GE Z-Wave On/Off Relay Switch (Model 45609) with a light almond wallplate installed. This illustrates the finished appearance of the switch in a standard electrical box.

5. Uputstvo za upotrebu

5.1 Ručna kontrola

The GE Z-Wave On/Off Relay Switch can be operated manually:

  • Press the top of the rocker switch to turn the connected device ON.
  • Press the bottom of the rocker switch to turn the connected device OFF.
  • An LED indicator on the switch illuminates to show its location in a dark room.

5.2 Z-Wave Network Inclusion (Pairing)

To add the switch to your Z-Wave network:

  1. Place your Z-Wave controller into inclusion (pairing) mode. Refer to your controller's instruction manual for specific steps.
  2. Once the controller is in inclusion mode, quickly tap the top or bottom of the rocker switch once. The LED indicator on the switch may flash to confirm inclusion.
  3. The controller will confirm successful inclusion. You can now control the switch remotely through your Z-Wave network.

Napomena: Pairing typically requires a light, quick tap, not a prolonged press.

5.3 Z-Wave Network Exclusion (Unpairing)

To remove the switch from your Z-Wave network:

  1. Place your Z-Wave controller into exclusion (unpairing) mode. Refer to your controller's instruction manual for specific steps.
  2. Once the controller is in exclusion mode, quickly tap the top or bottom of the rocker switch once. The LED indicator on the switch may flash to confirm exclusion.
  3. The controller will confirm successful exclusion. The switch is now removed from your Z-Wave network.

6. Održavanje

  • čišćenje: Da biste očistili prekidač, obrišite ga mekom krpomamp tkanina. Nemojte koristiti abrazivna sredstva za čišćenje ili rastvarače.
  • Nema dijelova koje može servisirati korisnik: There are no user-serviceable parts inside the switch. Do not attempt to open or repair the device.
  • Ažuriranja firmvera: Any firmware updates would be managed through your Z-Wave controller, if supported.

7. Otkrivanje problema

ProblemMogući uzrokRješenje
Light/Fan does not turn ON/OFF manually.
  • Nema napajanja na prekidaču.
  • Neispravno ožičenje.
  • Labave žičane veze.
  • Faulty bulb/fixture.
  • Proverite prekidač.
  • Verify wiring against Section 4.2.
  • Uvjerite se da su sve žičane veze sigurne.
  • Test with a known working bulb/fixture.
Switch does not respond to Z-Wave controller.
  • Not properly included in the Z-Wave network.
  • Kontroler je van dometa.
  • Interferencija.
  • Perform Z-Wave exclusion, then re-inclusion (Section 5.2, 5.3).
  • Move controller closer to the switch or add Z-Wave repeaters.
  • Ensure no other devices are causing wireless interference.
LED indikator ne radi.
  • Nema napajanja na prekidaču.
  • Neispravnost prekidača.
  • Check power and wiring.
  • Contact customer support if power is confirmed and LED remains off.

8. Specifikacije

FeatureDetalj
Broj modela45609 (ZW4001)
BrandJASCO (GE)
Snaga120VAC, 60Hz
Maksimalno opterećenje15A Resistive Load
Bežična tehnologijaZ-Wave
Konfiguracija ožičenja2-way or 3-way (with auxiliary switch)
Neutral WireObavezno
Dimenzije (D x Š x V)10.49 x 5.41 x 4.45 cm (približno 4.13 x 2.13 x 1.75 inča)
Težina113.4 g (približno 4 oz)
Način radaUKLJUČENO ISKLJUČENO
Tip prekidačaRocker
Vrsta montažeWall Mount (standard electrical box)
Tip kontroleraSmartThings (compatible with other Z-Wave controllers)

9. Garancija i podrška

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the JASCO Products webSačuvajte dokaz o kupovini za slučaj reklamacije.

JASCO Products provides customer support for their Z-Wave devices. Contact information can typically be found on their official webweb-mjestu ili na ambalaži proizvoda.

© 2023 JASCO Products. All rights reserved. GE is a trademark of General Electric Company and is under license by Jasco Products Company LLC.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.